Large Ceiling Units
|
|
Indoor Unit
Fujitsu General's larger capacity ceiling-mounted system are elegant in design, quiet in operation and yet still pack a mighty cooling and heating punch. System 36RSLX is popular where fresh air intake and high capacity is required like in a restaurant or bar. It is also often suspended from a threaded rod and used in multiples to condition large warehouse spaces. |
Outdoor Unit
|
|
Inverter Technology Through new, advanced technology, Inverter air conditioners are more economical to operate and quieter to run than conventional units. They can handle greater extremes in temperature, are smoother and more stable in operation, and reach the desired temperature more quickly than conventional air conditioners
. 4-Way Auto Louver for Balanced Comfort Airflow is automatically redirected left, right, up and down to provide a consistent temperature throughout a room.
Smart System: Auto Mode When the system is initially turned on, the fan speed is HIGH to reach the set temperature as quickly as possible. The fan speed will automatically adjust downward as the room begins to reach the set temperature.
Humidity Control This system features Dry Mode, which helps to control humidity levels, even when cooling may not be needed.
Fresh Air Intake Outside air can be introduced by attaching field supplied flexible duct to fresh air knockouts. Fresh air connection kit is Fujitsu part #KHRS940-25. (available through distributors)
Wired Remote Controller UTB-UUB (optional)
Features of the standard wired remote controller include: - Weekly timer - Set different on-off time by day - Set on-off time twice a day - Set time in 5 minute intervals - Control up to 16 indoor units - Child lock capable - Remote temperature sensor |
| Other Standard Features Include: |
| Sleep Timer |
Auto Changeover |
| 24-Hour Timer |
Cold Prevention |
| Auto Restart/Reset |
High Ceiling Mode |
| Low Ambient |
| |
| SYSTEM |
36RSLX |
| CAPACITIES: |
| Cooling BTU/h |
34,100 |
Outdoor Design Temp F° DB/WB |
95/75 |
| Heating BTU/h |
36,500 |
Outdoor Design Temp F° DB/WB |
47/43 |
| SEER |
14.0 |
| EER Clg/Htg |
8.1/10.4 |
| HSPF |
8.5 |
| Power Supply (V) |
208-230 |
| INDOOR UNIT: |
Noise Level db (A) Cooling Hi Med Lo |
48 45 41 |
Noise Level db (A) Heating Hi Med Lo |
48 43 39 |
| Weight (lbs.) |
106 |
| OUTDOOR UNIT: |
| Max Fuse Size (A) |
30 |
| Min. Ampacity (A) |
23 |
| Running Current Clg (A) Rated/Max |
18.3/18.8 |
| Running Current Htg (A) Rated/Max |
15.6/18.8 |
| Weight (lbs.) |
141 |
| REFRIGERANT PIPING: |
| Max Ht. Difference (ft.) |
98 |
Max Total or Combined Length (ft.) |
165 |
Discharge Vapor Line (O.D.) inches |
3/8 |
| Suction (O.D.) inches |
5/8 | |
|